SOFTRESET=NORMAL, AIS31TESTSEL=BEFORE, BYPNIST=NORMAL, BYPAIS31=NORMAL, FORCERUN=NORMAL, TESTEN=NOISE, ENABLE=DISABLED, CONDBYPASS=NORMAL, HEALTHTESTSEL=BEFORE
No Description
| ENABLE | TRNG Module Enable 0 (DISABLED): Module disabled 1 (ENABLED): Module enabled | 
| TESTEN | Test Enable 0 (NOISE): Non-determinsitc random number generation 1 (TESTDATA): Pseudo-random number generation | 
| CONDBYPASS | Conditioning Bypass 0 (NORMAL): The conditionig function is used 1 (BYPASS): The conditioning function is bypassed | 
| REPCOUNTIEN | IRQ enable for Repetition Count Test | 
| APT64IEN | IRQ enable for APT64IF | 
| APT4096IEN | IRQ enable for APT4096IF | 
| FULLIEN | IRQ enable for FIFO full | 
| SOFTRESET | Software Reset 0 (NORMAL): Module not in reset 1 (RESET): The continuous test, the conditioning function and the FIFO are reset | 
| PREIEN | IRQ enable for AIS31 prelim. noise alarm | 
| ALMIEN | IRQ enable for AIS31 noise alarm | 
| FORCERUN | Oscillator Force Run 0 (NORMAL): Oscillators will shut down when FIFO is full 1 (RUN): Oscillators will continue to run even after FIFO is full | 
| BYPNIST | NIST Start-up Test Bypass. 0 (NORMAL): NIST-800-90B startup test is applied. No data will be written to the FIFO until the test passes. 1 (BYPASS): NIST-800-90B startup test is bypassed. | 
| BYPAIS31 | AIS31 Start-up Test Bypass. 0 (NORMAL): AIS31 startup test is applied. No data will be written to the FIFO until the test passes. 1 (BYPASS): AIS31 startup test is bypassed. | 
| HEALTHTESTSEL | Health test input select 0 (BEFORE): Before conditioning 1 (AFTER): After conditioning | 
| AIS31TESTSEL | AIS31 test input select 0 (BEFORE): Before conditioning 1 (AFTER): After conditioning | 
| NB128BITBLOCKS | Number of 128b blocks in AES-CBCMAC | 
| FIFOWRSTARTUP | Fifo Write Start Up |